LD-81 Flood detector

The detector indicates room water floods (e.g. cellars, bathrooms). This information is sent to an alarm system for alert message transmission. It is connectible to an Oasis alarm system via a JA-81M wireless detector.

Flood detector

LD-81 Flood detector

Plug it into the IN1 input terminal (red wire) and GND (black wire). If the detector is triggered (e.g. by a water), it sends a trigger signal. If the detector goes into a stand-by condition, it sends a non-triggered signal. The LD-81 takes its power supply from the JA-81M´s circuit.

It is possible to use the LD-81 with an older type of detector, the JA-60N, for Profi systems if you insert a 4k7 resistor in series with the LD-81 between the INP (red wire) input terminals and GND (black wire).

Tekniske spesifiseringer

Operating environment II. internal
Operational temperature range -10 to +40 °C
Alarm condition water flood
Complies with EN 50130-4, EN 55022

Relaterte produkter

EI208DW Standalone CO detektor

Produktet vil detektere CO- (karbonmonoksid-)gass og gi tidlig varsel for å unngå de skadelige effektene av denne gassen på menneskers helse.

EI208W Standalone CO detektor

Produktet vil detektere CO- (karbonmonoksid-)gass og gi tidlig varsel for å unngå de skadelige effektene av denne gassen på menneskers helse.

GS-133 Gas Detector - 12 V DC

The GS-133 detector is used to indicate leaking of explosive gases (natural gas, methan, propane, butane). The detector detects two levels of gas concen-tration - different output reactions.

GS-208-CO Wired module for connection of the Ei208W(D) CO detector

This is a plug-in module designed for direct integration in the Ei208W or Ei208DW stand-alone CO detector that will enable its wired connection to a security or another system.

LD-12 Flood detector

The detector is a water flood indicator for rooms (e.g. cellars, bathrooms). This information is sent to an alarm system for alert message transmission.The LD-12 detector can be connected to the input terminals of alarm systems.

SD-283ST Wired combined smoke and heat detector with built in siren

Detector is used to detect fire hazards in the interior of residential or commercial buildings. The detector is also suitable for installing in caravan trailers or mobile homes. The product is not designed to be installed in industrial premises.

SD-503ST Stand-alone combined smoke and heat detector

The SD-503ST is used to detect fire hazards in the interior of residential or commercial buildings. The detector can be installed in mobile homes or caravans. The product is not designed to be installed in industrial premises.