JA-116H BUS expander – 16 inputs

Bus expander is used for powering and connecting up to 16 detectors with contact outputs. It is possible to install the module straight into the JA-106K control panel.

BUS expander – 16 inputs

Technical specifications

Power supply 12 V (9 … 15 V)
Current consumption (all outputs turned on) 25 mA
Warning: the consumptions of the detectors connected to the +U and GND terminals have to be added to the system power backup calculation.
Maximum acceptable load of one output from +U and GND 100 mA
Maximum acceptable load of all outputs from +U and GND 4 x 100 mA
Dimensions 102 x 66 x 20 mm
Weight 80 g
Classification Security grade 2/Environmental class II
- according to EN 50131-1, EN 50131-3, T014 (INCERT)
(valid when placed into a tamper-protected housing certified for no less then security grade 2/env. class II)
- loop inputs parameters single/double balanced
- number of detectors in one loop max. 5
- input balancing (optional) 1k, 2k2, 3k3, 4k7, 5k6, 10k
- recomended installation boxes JA-106K, PLV-CP-M, JA-194PL
- operational environment II., indoor general
- operational temperature range -10 to +40 °C
- operational humidity 75 % RH, no condensation
- certification body Trezor Test, ANPI
Also complies with EN 50130-4, EN 55022