Jablotron

JA-80G Wireless Gas Leak Detector

The mains-powered JA-80G senses combustive gas leaks using a hot platinum filament sensor. Wirelessly signals to alarms with a relay output to shut down electric gas valves. Enrollable to control panels, UC/AC relay receivers and JA-80L sirens

Wireless Gas Leak Detector

JA-80G Wireless Gas Leak Detector

The JA-80G detects mixtures of air and combustible gases or fumes (Natural Gas, Methane, Propane, Butane). The detector detects two levels of gas concentration, responding with two different reactions. The mains-powered detector indicates a gas leakage optically, and acoustically, and transmits alarm wirelessly via Oasis protocol.

 

Detector specifications

Sensitivity (concentration):
Methane Propane Iso-butane
First level 10 ± 3% LEL (0.50% vol) 18 ± 3% LEL (0.30% vol) 23 ± 3 % LEL (0.30% vol)
Second level 18 ± 3% LEL (0.80% vol) 30 ± 3% LEL (0.50% vol) 40 ± 3 % LEL (0.50% vol)
LEL = Lower explosive limit (100%) according to IEC 60079-20-1: for methane 4.4% volume concentration, for propane 1.7%, for iso-butane 1.3%, calibrated in the production of iso-butane
Mains 230 V (+10 to -15%) / 50 Hz, about 2 W, protection class II
Beep 94 db / 0.3 m
Relay Output optional response to 1st or 2nd level
Capacity of relay max 230 V / 5 A
Operational temperature -10 ° C to +40 ° C
Relative humidity 25 to 75%
Storage temperature -20 ° C to +50 ° C
Stabilization time 90 s
Response time to 10 s
Detection method catalytic combustion
Housing IP 30 (EN 60 529)
Communication band 868MHz, Oasis protocol
Communication range about 200 m in open area
Dimensions, weight 101 x 74 x 39, 210 g
Operating conditions ERC REC 70-03
Designed to operate at normal atmospheric pressures 86 to 106 kPa
Meets EN 50194-1, IEC 60079-29-1, IEC 50130-4, EN 55022, ETSI EN 300220, EN 60950-1
Intended for non-explosive areas - Zone 2 EN 60079-10
VVUÚ Certified by certification body No 3076

Note: Not suitable for use with hydrogen