JA-106K GSM Control panel with built-in GSM/GPRS/ LAN communicator

The JA-106K is a JA-100 alarm system control panel. It offers flexible settings and allows the smart protection of bigger family houses, offices, companies and apartment complexes. The settings are programmed by F-Link SW.

GSM Control panel with built-in GSM/GPRS/ LAN communicator

JA-106K GSM Control panel with built-in GSM/GPRS/ LAN communicator

The JA-106K offers

  • up to 120 wireless or BUS hardwired zones
  • up to 300 user codes
  • up to 15 sections
  • up to 32 programmable outputs
  • 20 independent calendars
  • the system reports to 30 users by SMS
  • 15 users have option of voice and SMS reporting
  • 5 ARC settings
  • 4 selectable reports to ARC

It has a built-in GSM/GPRS and LAN communicator on the board offering communication by voice, SMS or GPRS to end users or to ARC centers. It is equiped with a 1 GB memory card on the board for saving event reports, a voice menu and messages, storage of pictures and more.

The main control unit includes terminals:

  • 2x independent BUS terminals
  • 1x terminal for VOICE module
  • 1x terminal for built-in radio module (JA-110R)
  • 1x terminal for PSTN communication module (JA-190X)

Technical specifications

Control panel power supply ~ 230 V/50 Hz, max. 0.2 A, with T400 mA fuse,
protection class II
Back-up battery 12 V; 7 to 18 Ah
Maximum battery charging time 72 h
BUS voltage (red-black) 12.0 to 13.8 V
Max. continuous consumption from the control panel 1200 mA permanently, valid for each BUS output
(2000 mA for 10 minutes)
Max. continuous consumption for backing up 12 hours Without GSM communicator LAN – OFF – 1150 mA
LAN – ON – 1105 mA
With GSM communicator LAN – OFF – 1130 mA
LAN – ON – 1085 mA
Max. continuous consumption for backing up 24 hours Without GSM communicator LAN – OFF – 550 mA
LAN – ON – 505 mA
With GSM communicator LAN – OFF – 530 mA
LAN – ON – 485 mA
Max. number of devices 120
LAN communicator Ethernet interface
Dimensions 357 x 297 x 105 mm
Weight 2500 g
Reaction to invalid code entry Alarm after 10 wrong code entries
Event history approx. 7 million latest events, incl. date and time
Power supply unit type A (EN 50131-6)
T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC.
2G GSM communicator 850 / 900 / 1800 / 1900 MHz
3G GSM communicator 2100 MHz
Environmental class class II, indoor general according to EN 50131-1
Operational temperature range -10 °C to +40 °C, relative humidity 75%
Classification

Security grade 2 according to EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-10,

EN 50131-5-3, EN 50136-1, EN 50136-2

Operating frequency (with the JA-11xR module) 868.1 MHz
Radio emissions ETSI EN 300 220-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)
EMC EN 50130-4 ed. 2, EN 55022 ed. 3, ETSI EN 301 489-7
Safety EN 60950-1
Operational conditions ERC REC 70-03, ERC DEC (98) 20
Certification body TREZOR TEST: (JA-101K, JA-101K-LAN, JA-106K), ANPI: INCERT T014(A) (JA-101K, JA-106K)
Caller’s identification ETSI EN 300 089

Similar products

JA-107K GSM Control panel with LAN communicator

The JA-107K is an advanced version of the JABLOTRON 100+ security system. It is designed for large living spaces, offices and businesses. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.

Related products

JA-110T Bus short-circuit isolator module

The JA-110T bus isolator is designed to electrically seperate and protect vulnerable parts of the bus . It is powered by the bus. It can be installed in a JA-190PL box.

BP12-18 Universal back-up power supply

BP12-18 serves for power powering of device which need 12 V DC. The PLV-CP-L box is recommended for back-up batteries with capacities of 7 Ah - 18 Ah (a capacity of up to 26 Ah can be used with an external box).

JA-191Y LTE communicator module

The LTE communicator module is intended to be used with the JA-100K, JA-101K and JA-106K security alarm control panels of the JABLOTRON 100 series.