The JA-101K control panel offers flexible setting and allows easy protection for small premises, bigger family houses, offi ces and companies. The desired settings and the size of the system is programmed by F-link SW.
The JA-101K offers:
It has a built-in GSM/GPRS communicator on the board offering communication by voice, SMS or GPRS to end users or to ARC centers. It is equiped with a 1 GB memory card on the board for saving event reports, a voice menu and messages, the storage of pictures and more.
The main control unit includes terminals:
Control panel power supply | ~ 230 V/50 Hz, max. 0.1 A, with T200 mA fuse ~ 110 V to 120 V/60 Hz, max. 0.2 A, with T400 mA fuse, protection class II |
|
---|---|---|
Back-up battery | 12 V; 2.6 Ah | |
Maximum battery charging time | 72 h | |
BUS voltage (red-black) | 12.0 to 13.8 V | |
Max. continuous consumption from the control panel | 400 mA permanently (1000 mA for 5 minutes) | |
Max. continuous consumption for backing up 12 hours | Without GSM communicator | LAN – OFF – 123 mA LAN – ON – 78 mA |
With GSM communicator | LAN – OFF – 103 mA LAN – ON – 58 mA |
|
Max. continuous consumption for backing up 24 hours | Without GSM communicator | LAN – OFF – 37 mA LAN – ON – Not possible |
With GSM communicator | LAN – OFF – 17 mA LAN – ON – Not possible |
|
Max. number of devices | 50 | |
LAN communicator | Ethernet interface (LAN versions only) | |
Dimensions | 258 x 214 x 77 mm | |
Weight | 1250 g | |
Reaction to invalid code entry | Alarm after 10 wrong code entries | |
Event history | approx. 7 million latest events, incl. date and time | |
Power supply unit | type A (EN 50131-6) T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC. |
|
2G GSM communicator | 850 / 900 / 1800 / 1900 MHz | |
3G GSM communicator | 2100 MHz | |
Environmental class | class II, indoor general according to EN 50131-1 | |
Operational temperature range | -10 °C to +40 °C, relative humidity 75% | |
Classification |
Security grade 2 according to EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-10, EN 50131-5-3, EN 50136-1, EN 50136-2 |
|
Operating frequency (with the JA-11xR module) | 868.1 MHz | |
Radio emissions | ETSI EN 300 220-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM) | |
EMC | EN 50130-4 ed. 2, EN 55022 ed. 3, ETSI EN 301 489-7 | |
Safety | EN 60950-1 | |
Operational conditions | ERC REC 70-03, ERC DEC (98) 20 | |
Certification body | TREZOR TEST: (JA-101K, JA-101K-LAN, JA-106K), ANPI: INCERT T014(A) (JA-101K, JA-106K) | |
Caller’s identification | ETSI EN 300 089 |