The JA-110M bus module is used to connect wired magnetic door/window detectors to the bus and contains two independent inputs programmable to be NC/NO or using a balancing resistor.
Allows you to set a minimum time for alarm activation (0.5 s, 1 s, 2 s or 5 s).
The detector communicates with and is powered by the control panel bus. The detector is addressable and occupies two positions in the system.
SMART MEMORY indictaion (SMI) provides a visual (LED) verification of detector triggering. SMI is reset via the keypad.
Power | from control panel bus 12 V (9…15 V) |
---|---|
Current consumption in standby mode | 5 mA |
Current consumption for cable choice | 5 mA |
Maximum length of the connection cable between the input and the detector | 3 m |
Dimensions | 100 x 40 x 24 mm |
Classification | Grade II |
according to | EN 50131-1, EN 50131-3 |
Operational environment according to EN 50131-1 | II. Indoor general |
Operating temperature range | -10 °C to +40 °C |
Also complies with | EN 50130-4, EN 55022 |