JA-63 KRG "PROFI" Alarm system
The JA-63 "Profi" is a programmable modular control panel. Splitable into 2 sections (with a shared section). Built in power supply and ample space for a backup battery (12V, 1.3Ah or 2.6Ah).
| The JA-63K main board has 4 hard-wired inputs with programmable triggering (NC, balanced or double balanced) and programmable reactions. | |
|
Model JA-63KR (equipped with the "R" radio communicating module) has 16 wireless zones. Up to two JA-60 detectors can enrolled into each zone (totally 32 as a maximum). In total model 63KR has 20 zones (4 wired and 16 wireless). Up to 8 wireless controllers (remote controls or wireless keypads), a JA-60A wireless siren and unlimited number of UC family wireless output modules can be enrolled as well. If more zones are required, another JA-6x control panel can be enrolled as a subsystem (Master & Slave architecture). The master control panel receives information from the sub control panel and it can also arm and disarm the subsystem panel. For the easiest setting and supervision of the system, we recommend using the JA-80T interface along with Comlink software. |
|
![]() |
|
SecuTech Innovations Award 2003 |
Specifications
| Electrical | |
|---|---|
| Power | 230 VAC, max 0.1 A, supervised, class II |
| Backup battery | 12 V, from 1.3 or 2.6 Ah, normal life time 5 years |
| Backup power output | 13VDC, the max. permanent current is 0.4 or 1.2 A for max. 15 min (1 cycle per hour), self consumption of the control panel is 30mA |
| Hard-wired inputs | 4 input zones, selectable triggering: NC, EOL resistor or Double EOL resistor |
| Zone reactions | selectable: instant, delayed, panic, fire, 24 hour, next delayed |
| Wireless zones** | 16 zones (2 detectors can be enrolled to each = up to 32 detectors totally) |
| Frequency** | 433.92 MHz; digital hopping code; supervised communication |
| Keypads | max. 4 wired JA-60E keypads, max. 8 JA-60F wireless keypads** or RC-11 or JA-60D remote controllers ** |
| Access codes | master code and 14 user codes. When system is split, codes, detectors and remote controls can be addressed to particular sectors |
| Wired outputs | Alarm relay dry contacts 1A/60V; programmable outputs PgX & PgY (Chime, Fire, Arm, Panic, Alarm, Door, Home, AC failure), siren output (12 V, 0.7 A) |
| Wireless outputs** | control panel transmits signals for siren and PgX, PgY data for UC-2xx receivers |
| Events memory | 127 most recent events including date, time and detailed specification |
| Telephone communicator* | module 65X: digital communication to a monitoring station, 5 SMS messages or Pager dialing, 2 voice messages, modem communication with a remote PC (ComLink SW + JA-60U modem), remote keypad access with JA-60E and JA-60U |
| Monitoring station formats* | Contact ID, Ademco, Telemax, Franklin, Radionics, SurGard, DTMF2300, (198 reports codes) |
| * control panel equipped with telephone dialer JA-65X ** wireless control panel (JA-63KR, JA-63KRX) |
|
| Environmental | |
| Operating temperature | -10°C to 40° C |
| Operating humidity | max 80 % |
| Working environment | indoor use (class II, EN 50131-1) |
| Immunity | |
| Electrostatic discharge | 8 kV |
| RF immunity | 30 V / m |
| Physical | |
| Housing | plastic box with built-in power supply |
| Dimensions | see diagram bellow |
| Standards | |
| Complies with | EN 50131-1 (Grade 2), EN 50131-6, EN 300220, ETS 300 683, EN 50136, ETS 300001, TBR 21 |